Detecting Faults
Fault
The machine doesn't work
The machine blocks
frequently during juicing
The pressing units are not
synchronized
Peel ejector breaks
You can hear the motor
running but the pressing
units are not turning
Possible cause
Machine not plugged in.
No power is reaching the plug.
Cover not fitted properly.
Juice container not fitted
properly.
Blocked pressing units.
Safety sensors malfunctioning.
Faulty ON/OFF button.
Faulty circuit.
Insufficient voltage.
Faulty circuit.
Fault in an axle.
Peel ejector incorrectly fitted.
Internal fault.
Correction
Plug it in.
Check the socket.
Make sure it has been fit
properly.
Make sure it has been fit
properly.
Turn off the machine at the mains
and unblock the pressing units.
Contact your technical service.
Contact your technical service.
Contact your technical service.
Check that the voltage matches
that indicated in the manual.
Contact your technical service.
Contact your technical service.
Place it in its correct position
inserting it totally until observing
it has madecontact (Fig. 8)
Contact your technical service.