1. Install a 305 mm blade with a 15.9 mm arbour (or a
25.4 mm arbour with a 15.9 mm reducer) making sure the
rotation arrow on the blade matches the clockwise rotation
arrow on the upper guard, and the blade teeth are pointing
downward.
2. Place the laser collar (4) against the blade and on
the arbour. Thread the arbour bolt (4) on the arbour (Fig.
27) in a counterclockwise direction.
IMPORTANT: Make sure the flats of the blade collars
are engaged with the flats on the arbour shaft. Also, the flat-
side of the laser collar must be placed against the blade.
3. Place the blade wrench on the arbour bolt.
4. Press the arbour lock (5), holding it in firmly while
turning the blade counterclockwise. When it engages,
continue to press the arbour lock in, while tightening the
arbour bolt (4) securely. (Fig. 26)
5. Rotate the cover plate (3) back to its original
position until the slot in the cover plate engages with the
cover plate screw (2). While holding the lower blade guard,
tighten the screw with a Phillips screwdriver. (Fig. 26)
NOTE: The lower blade guard must be raised to the
upright position to access the cover plate screw.
6. Lower the clear retractable blade guard (1) and
verify the operation of the guard does not bind or stick. (Fig.
25)
7. Be sure the arbour lock is released so the blade
turns freely by spinning the blade until the arbour lock
disengages.
NOTE : Make sure the collars are clean and properly
arranged. Lower the blade into the lower table and check
for any contact with the base or the turn table by spinning
the blade manually.
CHANGING THE BATTERIES (Fig. 28)
Unplug your saw.
Failure to unplug your saw could result in accidental
starting causing possible serious personal injury.
1. Remove the laser guide from the saw.
2. Loosen and remove the two screws, then remove
the laser guide cover.
3. Remove the three batteries as arrow on Fig. 28 and
replace new batteries.
4. Replace the laser guide cover and two screws and
tighten.
NOTE: Replace the batteries with batteries that have
a rating of 1.5 volts (Number LR44).
When replacing the batteries, the battery cover should
be thoroughly cleaned. Use a soft paintbrush or similar
device, to remove all sawdust and debris.
CHANGING THE BELT (Fig. 29, 30)
Unplug your saw.
1. Loosen the bolts (1) and remove the belt cover.
2. Turn the screw (2) counter-clockwise with an Allen
wrench to move the motor to forward.
3. Remove and replace the belt.
4. Turn the screw (2) clockwise with an Allen wrench to
move the motor to rearward. Do not over tighten.
5. Replace the belt cover and tighten the bolts.

MAINTENANCE

WARNING! For your own safety, turn the switch off
and remove the plug from the power source outlet before
maintaining or lubricating your mitre saw.
NOISE AND VIBRATION
WARNING! Noise can be a health hazard. When
the noise level exceeds 80 dB(A), be sure to wear ear
protection.
The noise levels of this machine during cutting are as
follows:
Acoustic pressure, dB(A)
Sound-power level, dB(A)
Vibration acceleration, m/s
ACCESSORIES
Accessories and their corresponding order number
can be found in our catalogues.
GENERAL MAINTENANCE
Occasionally use a cloth to wipe off chips and dust
from the machine. And oil the rotary parts once a month to
extend the tool life. Do not oil the motor.
BRUSH INSPECTION
Check the motor brushes after the first 50 hours of
use for a new machine or after a new set of brushes have
been installed. After the first check, examine them every 10
hours of use.
When the carbon is worn to 6 mm in length or if
the spring or shunt wire is burned or damaged, replace
both brushes. If the brushes are found serviceable after
removing, reinstall them.

WARRANTY

See general warranty conditions printed on the
attached sheet.
DISPOSAL
In accordance with European Directive 2002/96/EC
relating to old electrical and electronic appliances and
its translation into national law, used electric tools must
be collected separately and recycled in an ecologically
desirable way.
SRF305/1800
SRF305/1800 E
100.3
89.4
111.03
102.4
1.235
1.5
2
13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Srf305/1800e

Inhaltsverzeichnis