Control elements
Position indicator (page 27)
Symbolizes the position of the fitting.
LED radio display
Every operation of the optional remote control will be
acknowledged by a flashing of the radio display.
CLOSE
Briefly push to close the drive.
OPEN to the parallel opening position
Briefly push to move the drive to the parallel opening
position.
OPEN to the turning position
Push for 1 s and the drive moves the window to
the turning position for normal, manual opening.
Timer-controlled ventilation
Briefly push once to move the drive to the parallel opening
position. After a ventilation time of 10 minutes, it moves
back to the closed position. Pushing the key again extends
the ventilation time by 10 minutes each time:
Pushed once: ventilate for 10 min.
Pushed twice: ventilate for 20 min.
Pushed three times: ventilate for 30 min.
Automatic/interval ventilation
Briefly pushing the automatic key activates automatic or
interval ventilation. If this is activated, the room will ventilated
in the parallel opening position for 10 minutes every hour.
Info
Briefly pushing the key will light up the symbols and display
the current modes for 20 s when darkened.
Programming key (page 27 and 30)
26/36
BDT 010-RC
English