ENGLISH
No coffee comes out
The machine does not
switch on
The thermoblock system
has overheated
Room temperature is too
low
Check the brewing system
60
CREMMAET TOUCH OCS
The ground coffee is too
1.
fine.
2.
The hopper is too full.
The filter in the brewing
3.
system is blocked.
No power supply.
1.
Voltage is not high
2.
enough.
The coffee machine is not
3.
switched on.
4.
The PCB is damaged.
Main power supply fuse
5.
is blown.
The temperature is above
160 °C.
Room temperature is 0 ºC or
lower.
The brewing system is not
correctly positioned. The
brewing system is damaged.
The motor of the brewing
system is damaged.
Turn the grinding level
1.
knob clockwise. The
higher the number
selected, the thicker the
coffee.
2.
Do not overfill the hopper.
Clean the coffee system
3.
using cleaning tablets.
If the problem persists,
please contact the official
Cecotec Technical Support
Service.
1.
Check that the appliance
is connected to the mains.
2.
Make sure that the
voltage is correct.
Check that the appliance
3.
is switched on.
1-5. Contact the official
Cecotec Technical
Support Service.
If the message "The hot water
thermoblock is cooling down,
please wait" appears on the
display, wait until the system
cools down.
Switch the machine back on
when the room temperature
is between 10 °C and 40 °C.
Press "Check up". Replace the
brewing system. Replace the
motor.