Remove the front plastic enclosure (S) [Fig.11] by
opening its locks with the standard key.
Remove rear door (2) and plastic panel (1) both
located on the right side of the machine.
Remove 4 fixing bolts (1) and remove the electrical
motor from the turbine body.
KOBRA Cyclone
Open the square shaped aluminium cover located on
the motor and disconnect wires from the electrical
motor.
IMPORTANT: BEFORE DISCONNECTING THE WIRES
FROM THE ELECTRICAL MOTOR TAKE A WRITTEN
NOTE OF THE WIRING CONNECTIONS (DELTA
Y) AND OF THE SEQUENCE OF THE THREE PHASES
R-S-T WIRES OF THE MOTOR.
Install new motor by following the same electrical
connection and follow all steps backward to re-
assemble the machine.
8.4
HOW TO REPLACE THE VACUUM
SYSTEM MOTOR (Tav. G, pag. 14)
This is a service operation which needs to be performed
by qualified service people in case of failure of the
vacuum system motor.
DISCONNECT the Cyclone from main power supply
by turning the main switch (U) [Tav.D-Fig.2] into "0"
position and disconnect the plug of the power cord
from main power supply.
Open rear back doors of the Cyclone.
Remove plastic waste bag from its position.
Remove trolley by releasing the two metal fixing
pins.
Remove metal cover by loosing the 4 fixing screws.
It is now possible to access to the electrical motor.
Disconnect two wires of the electrical motor from
connector.
Loose and remove the 4 screws fixing the motor to
the machine.
Remove the vacuum system motor from its position.
Replace vacuum system motor with the new motor
by using the same fixing plate.
The machine can now be re-assembled by following
the above steps backward.
Vacuum System motor has an operating lifetime of 700-
1000 hours.
35
OR
DI-129/13/14.04.2022