• The turbo dirt miller (26) with its rotat-
ing water jet is particularly suitable for
working with low water consumption.
• The standard Vario nozzle (25) with its
flat jet is particularly suitable for sur-
face cleaning.
If you turn the nozzle tip to the left you
will increase the pressure. If you turn
the nozzle tip to the right you will re-
duce the pressure.
• The rotating washing brush (21) is basi-
cally used without pressure exertion.
The cleaning function results from the
rotary movement and the water flow.
The wash brush does not rotate if the
water flow is missing.
In the event of leaks in the
water system, switch off the
equipment immediately at the
on/off switch (8) and discon-
nect the equipment from the
mains at the mains power
cord. Risk of electric shock!
Start afresh with making the
water connections (cf. "Start-
up/Operation" from point 2.).
If there is still air in the device,
please proceed as follows:
To vent the supply hose:
1. Remove the quick connector for garden
hose adapter (22) on the water connec-
tion coupling (12) and turn the water
tap on until the water comes out with-
out bubbles.
2. Switch off the water tap.
3. Connect the supply hose to the water
connection (12) on the equipment using
the quick connector for garden hose
adapter (22).
4. Fully open the water tap.
To vent the equipment:
5. Switch on the on/off switch (8) until
pressure has built up.
26
6. Switch off the on/off switch (8).
7. Press the on lever (19) on the gun (14)
until the pressure has gone.
8. Please repeat process 5. to 7. a few
times until there is no more air in the
device.
• You can lock or unlock the start le-
B
ver (19) of the spray gun (14) by
pressing the locking button (20).
Lock the starting lever to prevent
the pressure cleaner from be-
ing inadvertently / accidentally
started.
Interrupting operation
• Release the lever (19) of the gun (14).
• During prolonged work intervals turn
off the pressure cleaner by its ON /
OFF switch (8).
If the equipment falls over,
switch off the equipment
immediately at the on/off
switch (8) and disconnect the
equipment from the mains at
the mains power cord. Risk
of electric shock! Only now
should the equipment be re-
turned to an upright position.
For your own safety, wait
approx. 5 minutes before re-
connecting to the electricity.
Ending operation
1. After having worked with a detergent
rinse the pressure cleaner with clear
water.
2. Release the lever of the gun (14).
3. Turn off the pressure by its ON / OFF
switch (8). Disconnect the mains plug.
4. Turn off the water tap.
5. Disconnect the pressure cleaner from
the water mains.