Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA PG43SA-D Betriebsanleitung Seite 17

Druckmessgerät mit integrierter plattenfederüberwachung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Specifications
9.2 Overpressure safety and vacuum safety
Scale range
bar
psi
1) Observe max. pressure rating (PN) of the process connection, see tables in data sheet PM 04.17
Vacuum safety
All scale ranges are suitable for the vacuum typical of CIP or SIP
cleaning. Positive scale ranges < 6 bar (< 100 psi) and optionally
vacuum-tight ranges to -1 bar are available.
WIKA operating instructions pressure gauge, model PG43SA-D
0 ... 2.5
0 ... 4
0 ... 6
0 ... 10
0 ... 16
-1 ... +1.5
-1 ... +3
-1 ... +5
-1 ... +9
-1 ... +15
0 ... 36
0 ... 60
0 ... 100
0 ... 160
0 ... 200
-30 inHg ... +30
-30 inHg ... +60
-30 inHg ... +100
-30 inHg ... +150
Overpressure
safety
1)
4
8
18
40
40
4
8
18
40
40
58
120
300
580
580
58
120
300
580
EN
17

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ns 100

Inhaltsverzeichnis