2.2
Regeneration
• Exchange of hardness forming substances
ions from the regenerative at the ion exchanger.
• A precision brine meter measures out the brine required.
• The product is equipped with a device that disinfects the ion exchange
material during regeneration.
• By measuring data acquisition during brine extraction, the regener-
ation process is adapted to the respective pressure conditions, the
regenerative and regeneration water consumption is reduced to the
required minimum.
• The optimised brine preparation process produces as much brine as
needed for regeneration
in less than 0.5 hours.
• The brine collects in a special sink of the regenerative container and
is fully extracted from there. After brine extraction, there is no liquid
left in the regenerative container.
• An ultrasound sensor in the Easy Fill technology cover measures the
regenerative level.
• The regeneration is proportional. 100% regeneration takes place after
72 hours at the latest for hygiene purposes.
2.3
Regenerative
monitoring
• 100% in the multi-info touch display corresponds
filling level of approx. 46 cm.
• From a level of around 20%, the device status indicator changes from
"blue" to "yellow" to signal a need to refill the regenerative.
2.4
Mufti-info
touch display
The product is equipped with a touch display. It can be operated intuitively
and provides a quick overview of all product parameters.
During start-up, you can select basic parameters on the display:
• Country-specific
settings at the location of operation
• Unit for measuring water hardness at the location of operation (OdH,Of,
mollm3, ppm calcium carbonate)
• Inflow water hardness (enter manually or input the value stored in the
hydromaps
water hardness database for the location of operation)
Desired
outlet
water
hardness
Depending on your settings, you will see the current parameters on the
display during operation:
• Current flow volume in Vh (fully softened water plus inflow water)
Inflow water
Outlet water
flow volume in Ilh
valve __b
Fullysoftened water
= cfisplayed v olurnein litres
NOTE
A comparison Ofthe displayed volumes using a domestic water
meter is not possible.
• Water and regenerative consumption
• Regenerative level (via ultrasound sensor in the Easy Fill technology
cover)
• Reminders for filter backwashing,
nance
work
Ca and Mg ions for Na
to a regenerative
filter change and other mainte-
2.5
Interaction
A BWT mineral metering unit can be plugged into the unit at any time.
Up to 10 AQA Guard Wireless Water Sensors (order no. 11772) can
be taught.
2.6
Connectivity
BWT DES( DES Digital Eco System)
Various functions may be available depending on the product and market:
• GSM connection
to the server for full functionality
updates.
• Wi-Fi or LAN connection to your local network to control and monitor
the product via PC, smartphone or tablet.
EnOcean@
interface
for the AQA
Connectivity
extends the functionality
system to be registered in order to use advanced operating and main-
tenance functions via the BESTWATERHOMEapp.
NOTE
Dependingonthe
2.7
Safety
2.7.1
AQA
Safe
valve
• The
AQA
Safe
valve
closes
the waste
power failure and thus protects against water damage caused by
rinsing water, especially when the rinsing water is being drained by a
pump that stops functioning when the power fails.
2.7.2
AQA Watch
alarm
function
• The programmable
AQA Watch alarm function monitors the water
supply to the building and issues a warning
rates (< 60 1/h) over a longer period of time (> 10 minutes) indicate
a problem in the pipe network (e.g. leakage, dripping drain tap or
leaky toilet cistern).
2.7.3
AQA Stop —moisture
on floor
• If the products
floor sensor detects water on the floor, the water
supply in the direction of flow from the unit is shut off and a waming
issued. The floor sensor only responds to drinking water (minimum
conductivity of 500 pS/cm).
AQA Stop —water quantity
limitation
• To minimise water damage, the control valve shuts off the water
supply downstream
of the product following continuous
preset water volume.
• If larger quantities of water are to be drawn without interruption (e.g.
to fill a large whirlpool, swimming pool, etc.), this function may need
to be deactivated
or acknowledged
continuous
flow
must
be observed.
AQA Guard Wireless
Sensor (optional)
• Installation of up to 10 AQA Guard Wireless Water Sensors (order no.
11772) in the building to receive an alarm message in case of leakage.
NOTE
The maximum
amount
Sensorandthesystem dependson the building architecture,installed
material
and Other external
Dependingon the product, not all safety functions are available.
and database
Guard
function.
of the product and allows the
notall typesof connectivityareavailable.
water
valve
in the
event
of a
message if low flow