Data recording:
Weight:
Protection:
EMC:
Error messages:
Err 0*
Err 3*
Err 4**
Err 5*
* Please send the device back for checking
** Please check input signal and programming
Cleaning:
7. Delivery specification
• Digital display
• Panel mounting clip
• Bezel for screw mount, panel cut-out 50 x 25 mm
• Bezel for clip mount, panel cut-out 50 x 25 mm
• Sealing
• 1 sheet with self-adhesive symbols
via EEPROM (capacity :
1x106 recording cycles
or 10 years)
appr. 50g
IP 65 (on the front)
EN 61 000-4-2 ;
EN 55011 class B ;
EN 61 000-6-2
Error/defect in A/D-part
Error/defect EEPROM
Analogue input overflow
Error/defect EEPROM. De-
vice not calibrated
The front side of the device
is to be cleaned only with a
wet cloth.
8. Operating examples :
8.1 Weight measurement with totaling
A throughput measurement is to be used to define
the quantity of granulate. The measuring sensor
delivers 20 mA at full throughput (= 10 kg/second).
The measuring range selected will be the one
ranging from 0 to 20 mA. Allocate 0 to the lowest
input signal, 10 to the highest input signal. To dis-
play the added value in tons, set the factor to
0.001.
Attention: the decimal point is only used for dis-
playing purposes. With a momentary value display
of 10.0, the value 100 would be added in the
adding counter! This point is to be considered ac-
cordingly when setting the factor.
If the momentary throughput is to be displayed
with one decimal, the factor is to be set to 0.0001.
The values displayed can be shifted freely within
the display range
A reversed allocation of the value to be displayed
to the signal allows to program also descending
operating curves. In this case, the device does not
display the filling level any more, but the quantity
removed.
5