Herunterladen Inhalt Inhalt Diese Seite drucken

Value Range For Operating Mode - Fronius Ri Fb Inside/I Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RI FB Inside/i:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

HEX
address
Signal
F007
Control Flag Group 8
Bits 0 to
15
F008
Operating mode
Bit 0
Bit 1
Bit 2
Bit 3
Bits 4 to
15
F009
Job number
F00A
Program number
F00B
Power
F00C
Arc length correction
F00D
Pulse-/dynamic correction
F00E
Reserved
F00F
Reserved
F010
Reserved
F011
Reserved
F012
Reserved
F013
Reserved
F014
Reserved
F015
Reserved
F016
Reserved
F017
Reserved
F018
Reserved
F019
Reserved
F01A
Reserved
F01B
Reserved
F01C
Reserved
F01D
Reserved
F01E
Reserved
Value Range for
Operating Mode
62
Reserved
Operating mode 0
Operating mode 1
Operating mode 2
Operating mode 3
Reserved
Bit
4-15
Bit 3
Bit 2
-
0
0
Type
Boolean
Boolean
Boolean
Boolean
Boolean
Byte
Byte
Word
Word
Byte
Bit 1
Bit 0
Description
0
0
MIG standard
Range / Unit
Factor
Value
See table
Range for Ope-
rating Mode
on
page
62
0 to 255
0 to 127
0 to 65,535
(0 to 100%)
0 to 65,535
(-10 to +10%)
0 to 255
(-5 to +5%)

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ri mod/i cc-m40 modbus tcp-2p

Inhaltsverzeichnis