General

Safety

Incorrect operation and faulty work can cause serious personal injury and mate-
rial damage.
All work and functions described in this document must be performed only by
trained specialist personnel who have read and understood the following docu-
ments in full:
Connections and
indicators on the
RJ 45 module
(11)
(12)
(13)
(14)
Network status LED:
Status
Off
Lights up green
Flashes green
Lights up red
Flashes red
40
WARNING!
this document
the Operating Instructions of the robot interface "RI FB Inside/i"
all documents relating to system components, especially the safety rules
(9)
(10)
(1)
(3)
(5)
(7)
(2)
(4)
(6)
(8)
(13)
(14)
RJ 45 Ethernet connection 2
RJ 45 Ethernet connection 1
Connection/Activity 1 LED
Network status LED
Meaning
No IP address or exception state
At least one Modbus message received
Waiting for first Modbus message
IP address conflict, serious error
Connection timeout. No Modbus message was received
within the period defined for the "Process active time-
out"
(1)
TX+
(11)
(12)
(2)
TX-
(3)
RX+
(6)
RX-
(4)
Not normally used; to ensure
signal completeness, these
(5)
pins must be interconnected
(7)
and, after passing through a
filter circuit, must terminate
(8)
at the ground conductor (PE).
(9)
Connection/Activity 2 LED
(10)
Module status LED