Herunterladen Inhalt Inhalt Diese Seite drucken

Data Transfer Properties; Configuration Parameters - Fronius Ri Fb Inside/I Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RI FB Inside/i:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Network Status LED:
Status
Flashes green
Lights up red
Flashes red
Module Status LED:
Status
Off
Lights up green
Lights up red
Flashes red
Alternates between
red and green
Link/Activity LED:
Status
Off
Lights up green
Flickers green
Lights up yellow
Flickers yellow
Data Transfer
Transmission technology
Properties
Ethernet
Medium (4 x 2 twisted-pair copper cable)
Category 3 (10 Mbit/s)
Category 5 (100 Mbit/s)
Transmission speed
10 Mbit/s or 100 Mbit/s
Bus connection
RJ-45 Ethernet / M12
Configuration
In some robot control systems, it may be necessary to state the configuration pa-
Parameters
rameters described here so that the bus module can communicate with the ro-
bot.
Parameter
Vendor Name
Product Code
42
Meaning
Waiting for first Modbus message
IP address conflict, serious error
Connection timeout. No Modbus message was received
within the period defined for the "Process active time-
out"
Meaning
No supply voltage
Normal operation
Major error (exception state, serious fault, etc.)
Minor error
Firmware update in progress
Meaning
No connection, no activity
Connection established (100 Mbit/s)
Activity (100 Mbit/s)
Connection established (10 Mbit/s)
Activity (10 Mbit/s)
Value
Fronius International GmbH
0301
(769
)
hex
dec

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ri mod/i cc-m40 modbus tcp-2p

Inhaltsverzeichnis