Herunterladen Inhalt Inhalt Diese Seite drucken

MasterCool COMMANDER1100 Bedienungsanleitung Seite 24

R134a aufbereitung/recycling/aufladen
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
To Fill Fresh Oil Bottles:
1.
Carefully disconnect the quick connect on desired oil bottle.
2.
Carefully remove from holder.
3.
Unscrew the top cap only on the bottle (see instruction sticker on cap).
4.
Refill with proper fresh oil, push the bellow from the bottom until a little amount of oil comes out.
Screw on top cap, connect quick connect, ensure that hose going into machine is not bent.
Automatic Refrigerant Charge
The machine will now automatically charge the pre-programmed amount of refrigerant.
The following will be displayed:
Tank graphic and weight of refrigerant
Numerical value of refrigerant charged
Total weight of refrigerant to be charged
Tank pressure and temperature
Vehicle system pressure
End of Charge / Hose Clearing Process
Follow the instructions on the screen:
1.
Close the high and low side valves on the machine, press next to continue.
2.
Start the vehicle engine and turn AC system on high, press next to continue.
3.
Verify the high and low side system pressures. Press next to continue.
4.
Turn off the vehicle and allow the AC system pressures to equalize.
5.
Close and remove the high side coupler. Press next to continue.
6.
Start the vehicle, turn the AC system on high. Press next.
7.
Open the valves on the machine. Press next.
8.
Allow the AC system pressures to equalize. Press next
9.
Close and remove the low side coupler, turn off the vehicle. Press next.