USED OIL BOTTLE: All machines have a used oil bottle, be sure to periodically dispose of the used oil in
•
an appropriate container.
NOTE: When installing the used oil bottle, be sure not to bend the hose or allow the hose to be pressed
against the back wall behind the bottle.
INTERNAL TANK FILLING:
•
1.
Press the small arrow on the left side of the computer command center screen to access the
MAIN MENU.
2.
Press the maintenance button.
3.
Press the tank filling button.
4.
The tank filling screen will be displayed. Tank filling is preset to 15 pounds for optimal
performance. Press next.
5.
The preset 15 pounds is the total amount of refrigerant in the tank. To change to a different
amount, press "c" to clear then enter the total amount of refrigerant you want the tank to end up
with.
6.
Follow the steps displayed on the screen.
7.
Remove the tank adapter that is stored on the side of the machine between the hose holders.
Connect the tank adapter to the external refrigerant source. The high side coupler will connect to
the tank adapter allowing access to the external refrigerant source.
8.
Connect the high-side (red) coupler to the external tank and press next.
9.
Open the high-side coupler by turning it completely clockwise, press next.
10. Open the valve on top of the external tank and press next.
11. Turn the external tank upside down for liquid flow and press next.
12. Open the high-side valve on the machine and press next.
13. The machine will now start to fill the internal tank and will automatically shut off when the tank is
filled to approximately 15 pounds or the target amount has entered the internal tank.
NOTE: The filling process can be stopped at any time by pressing exit.
14. When tank fill has completed, close the valve on the external tank.
15. Turn the red coupler on external tank completely counterclockwise and remove.
16. Press next; the machine will automatically recover the remaining amount of refrigerant in the
machine's hoses.
17. The machine is now ready for operation. Press the arrows in the middle left of the screen to
return to the start screen.
COMMANDER MACHINE BASIC OPERATION
Once the initial setup of the machine has been completed the machine is ready for operation.
The AUTOMATIC/MANUAL SCREEN will appear on the COMMANDER2100 (-E)/COMMANDER3100 (-E). The manual
screen will appear on the COMMANDER1100 (-E).
Choose the reclamation procedure desired.
AUTOMATIC (COMMANDER2100 (-E)/COMMANDER3100 (-E) ONLY): Recover, vacuum, vacuum
•
leak test, oil injection (COMMANDER2100 (-E), COMMANDER3100-E only) and refrigerant charge in
continuous process.
MANUAL: Recover, vacuum, oil injection (COMMANDER2100 (-E) only) or refrigerant charge can be
•
done individually.
NOTE: The top of the screen will display language, pressure, temperature, units' of measure for refrigerant, oil
charge, time and date. To change these settings please refer to the main menu instructions at the beginning of this
manual.
18