o
HOSE FLUSHING (COMMANDER3100 (-E) ONLY):The hose flushing capability on the
COMMANDER3100 is used when switching from a standard R134a vehicle to a hybrid R134a
system. This process is incorporated to ensure the removal of any non-compatible oil when
switching from a standard to a hybrid system.
WARNING: Failure to hose flush prior to servicing a hybrid can cause irreversible damage to
the A/C system and could cause the A/C compressor to conduct a deadly amount of electrical
current.
Follow the instructions displayed on the screen.
•
DOCUMENTS: Set up and operational information of the machine.
16
1.
Connect the couplers to the flush fittings on the side of the machine.
2.
Open the couplers by turning the knobs completely clockwise.
3.
Open the red and blue valves on the front of the machine. Press next to continue.
4.
The machine will now run a hose flushing cycle. This could take several minutes to
ensure the removal of non-compatible oil. Press done to return to main screen.
www.mastercool.com