3.2.3. Aufladen der LiFePO
[en] Battery chargers that are not connected to the System+ port must interrupt the charging process in case of imminent
overvoltage or overtemperature of the cells. The Charge disconnect output of the Smart BMS can be used for this purpose.
[en] The Charge disconnect output is normally high (equal to battery voltage) and switches to open circuit state in case of
imminent cell overvoltage.
[en] Battery chargers with a remote on/off terminal that activates the charger when the terminal is pulled high (to battery plus)
and deactivates when the terminal is left free floating can be controlled directly with the Charge disconnect output. See the
Anhang A: [11]
for a list of Victron products with this behavior.
[en] Alternatively, a Cyrix-Li-Charge can be used. The Cyrix-Li-Charge is a unidirectional combiner that inserts in between a
battery charger and the lithium battery. It will engage only when charge voltage from a battery charger is present on its charge-
side terminal. A control terminal connects to the Charge disconnect of the Smart BMS.
3.2.4. Batterie
• Bei mehreren Batterien in Parallel- bzw. Reihenschaltung sollten die beiden M8-Rundsteckverbinder-Steckersätze jeder
Batterie in Reihe geschaltet werden (Verkettung). Verbinden Sie die beiden verbleibenden Kabel mit dem Smart BMS.
Seite 5
Smart BMS 12-200
-Batterie mit einem zusätzlichen Ladegerät
4