Herunterladen Inhalt Inhalt Diese Seite drucken

Functions In Service Mode; Resetting The Runtime - Selve commeo Betriebsanleitung

Vorschau ausblenden Andere Handbücher für commeo:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

iveo initial operation/Setting

5.3. Functions in service mode

In order to carry out the following settings, the receiver has to be put into service
mode by disconnecting it from the mains supply in a special way.
Consider the following:
• Transmitter programmation has to be finished before service mode can be
executed.
• Put only the receiver which is to be set into service mode.
• The receiver remains in service mode for 4 minutes.
• In order to leave the service mode just drive the motor/receiver up or down.
Fuse
3 s
3 s
The receiver confirms the service mode by a brief up and down moving.

5.4. Resetting the runtime

Setup-mode can only be finished by programming both end positions. The transmit-
ter assignment is not affected by this. When setting the end positions, the motor/
receiver is in the normal operating state again.
Put the motor/receiver into service mode by disconnecting it. Press the STOP button
of an assigned transmitter for 6 seconds to return the motor/receiver to setting
mode (wait until the transmitter indicator flashes twice). Then set the runtime as
described in the grey section for item 5.
Fuse
3 s
3 s
3 s
Assigned transmitter
3 s
40
STOP 6 s