iveo initial operation/Setting
5. iveo initial operation/Setting
iveo initial operation
The iveo initial operation is possible using any iveo or intronic transmitter which has
UP, STOP and DOWN buttons.
Operation
1 s
1 s
or
3 s
or
3 s
Drive
Press the UP and DOWN buttons at the transmitter
at the same time. The transmitter is temporarily
programmed into the receiver.
To save the programmed transmitter, press the
PROG key for one second. The transmitter is now
permanently programmed in the receiver.
Now set the run times:
Move the blind to the lower end position with the
UP or DOWN button.
Press the STOP button of the transmitter for 3 sec-
onds. The correct rotation direction assignment will
be carried out at the end of the end position set-
ting.
Move to the upper end position.
Press the STOP button of the transmitter for 3 sec-
onds. The runtime/rotation direction is now set.
Perform a test run.
38