Herunterladen Diese Seite drucken

Lenz Digital plus LF100XF Information Seite 40

Verfügbare Sprachen

Verfügbare Sprachen

40
29
Bit
Settings 1
Here you can influence several features. Alterations are best carried
out in the binary mode (see the operating manual of the manual control
LH100).
1
Direction of locomotive
0
1
2
Running-notch mode: Even if the LF100XF does not drive a motor, the
running-notch mode has to be selected correctly. Only then can the
direction-dependent lighting work correctly.
0
1
3 - 5
Not used
6
0
2
This setting can be ignored when programming the 4-digit address with
the command station LZ100 and manual control LH100.
7-8
not used
normal: locomotive is driven forwards if the arrow on the manual
control points upwards.
exchanged: locomotive is driven forwards if the arrow on the
manual control points downwards.
Operation with 14 or 27 running notches. This setting is selected if
the locomotive decoder is operated with digital systems which do
not support the 28 running-notch mode.
Operation with 28 running notches.
This setting is selected for digital systems which support the 28 or
128 running-notch mode.
Decoder uses basic address 1-99 (from CV1)
Decoder uses extended address 100-9999 (from CV17 and CV18)
Information LF100XF
[2]
0
1
0
0
0
loading

Diese Anleitung auch für:

10104