This appliance can be used for cooling, dehumidifying and ventilating. When switching between modes, the fan
continues to rotate but the compressor stops: the compressor will start after 3 minutes. This delay protects the compressor
from potential damage.
Cooling, Fan
THE DRAINAGE TUBE MUST BE CONNECTED to the appliance AT ALL TIMES: the only exception is when the
appliance is used in dehumidification mode only, in which case the appliance should be left to discharge directly
into the room for maximum efficiency (see the "Dehumidification Mode" paragraph).
Clean the air filter under the easily removable rear grille regularly to keep the air conditioner working efficiently.
1. COOLING MODE (COOL)
Press the MODE button until the cooling mode is selected, the LED
The temperature adjustment range is from 16°C to 32°C.
In this mode, every time you press the ON/OFF button, the unit turns off, the appliance memorizes the set
temperature and will maintain the setting when it is turned back on.
In this mode it is possible to adjust the fan speed (fan Speed button), set the Timer and the SLEEP function (only
from the remote control).
For quieter operation, reduce the speed to minimum (low).
2. DEHUMIDIFICATION MODE (DRY)
Press the MODE button until the dehumidification mode is selected, the LED
The temperature is controlled by the electronic board and cannot be adjusted. In this mode, every time the
unit turns off by pressing the ON/OFF button, the appliance memorizes the settings and will retain them when
turned on again.
The fan speed is fixed at low and cannot be adjusted
NOTE: the air conditioner does not cool the room when operating as a dehumidifier. When the appliance is
used as a dehumidifier, the flexible pipe must not be connected. For maximum dehumidification efficiency, leave
the rear discharge attachment free to discharge directly into the environment. The dehumidification mode is
recommended during autumn and winter. If used during summer, it is best to leave the flexible pipe attached so
that the hot air is discharged towards the outside rather than into the room. During dehumidification, continuous
drainage should be implemented (see the next chapter, "HOW TO ELIMINATE CONDENSATE").
3. FAN MODE (FAN)
Press the MODE button to select ventilation until the corresponding icon
In this mode, the fan speed can be adjusted.
The temperature cannot be adjusted.
V 01/24
HOW TO USE THE APPLIANCE
OPERATING MODES
Dehumidifying
on the control panel lights up.
on the control panel lights up
appears.