Common Radio Group
• All devices of the radio group or
common radio group issue alarm
Alarm Stop
For when an alarm sounds but you
are absolutely certain that there is
no fire!
Radio group or common radio group
• Briefly press Test/ Stop button on
any alarm
• Alarm stops
• Signals are not forwarded to other
units
If the signal has already been
forwarded:
• Briefly press Test/ Stop button
on the originating device
• Alarm is silenced on all
connected devices
Briefly press Test/ Stop button on one
of the forwarding alarms:
• Alarm is silenced on all forwarding
devices
• Alarm on originating device contin-
ues to sound
• An easy way to locate the originat-
ing device in the event of a fire
– 52 –

MOUNTING

The smoke alarm unit is held in place
by a magnetic holder attached to the
mounting site. Please note that the
magnetic holder only has a strong
attractive force from one direction.
The magnetic holder may be mounted
either by an adhesive fixing or by
drilled holes:

1. Adhesive Mounting

1.1 Adhesive mounting of magnetic
carrier, self-adhesive coated in
accordance with EN14604:2005/
AC:2008
The sole use of this self-adhesive
fastener produces a
• very maintenance-friendly
• firm
• magnetic connection of the device
to the installation site.
• The alarm unit can be removed by
gently pulling downwards from the
magnetic holder e.g. for inspection,
maintenance or cleaning. For this
adhesive mounting, only the
adhesive supplied may be used.
The mounting site must be
• firm
• dry
• free of dust, grease or loose paint,
etc.
Application:
a) Remove the information sticker
and the protective film from the
self-adhesive surface (Fig. 3) of
the magnetic holder.
b) Press the adhesive surface of the
magnetic holder for approx.
10 seconds firmly onto the
mounting surface.
c) Fit the alarm unit onto the
magnetic holder.
d) The adhesive bond will reach its
final strength after approx. 72 hours.
e) If required, the unit can be remo-
ved from the magnetic holder by
pulling it gently vertically away
Fig. 3
1.2 Adhesive mounting using optional
fixing material (thin double-sided
adhesive film) as per vfdb (German
Fire Protection Association) 14/01