Ground Floor Radio Group
max. 15 units
1st Floor Radio Group
max. 15 units
2nd Floor Radio Group
max. 15 units
3rd Floor Radio Group
max. 15 units
The Radio Group as
Common Radio Group
max. 14 radio groups
possible plus CRG stairway
Activate the group you wish to be
the common radio group (e.g. in
stairway):
1. Press black activation pin into
marked opening of one of the Stair-
way group alarms and hold until LED
lights yellow; continue to hold until
LED blinks yellow.
2. Pull activation pin back, then, for
all alarms added to the radio group
thus far:
LED flashes periodically for approx.
10 minutes
Radio Group EG
1. On the next alarm to the stairway
from the Ground Floor radio group,
press the black activation pin:
LED
1 second
Signal:
short yellow pulse
(lights only very briefly)
Meaning:
Testing in progress,
please wait!
LED
3 seconds
Signal:
green steady signal
Meaning: Connection successful bet-
ween Ground Floor radio
group and Stairway radio
group
– 48 –
Now repeat this procedure
with the second, third and
fourth radio groups to link
these with the Stairway
radio group.
Completing Setup of a
Common Radio Group
Once all the radio groups of the
flats are linked to the Stairway radio
group, exit connection mode as
follows:
• On any alarm in the Stairway radio
group
• Press radio button with black
activa tion pin for 2 seconds
• Stairway radio group is set as
common radio group
• All LEDs on connected
alarms go out
Common Radio Group
Connection Test
Press and hold Stairway
common radio group
for 2 – 3 seconds
Beep
1x
Beep issued only on this alarm
Wait approx. 10 seconds until 2nd
beep:
Beep
1x
Beeps on all alarms in the common
radio group but not in the other
radio groups !
This test should be performed regu-
larly, every 3-6 months, to check the
common radio group.
Connection Test between
a Radio Group and the
Common Radio Group
e. g. Ground Floor
radio group
Press and hold approx. 20
seconds Hold down on this
alarm until 3rd beep (do not
release earlier!)
– 49 –