Pull out red activation
button to switch
unit off.
LED SIGNALS
LED:
1 second
Signal:
short yellow pulse
(lights only very briefly)
Meaning:
Testing in progress,
please wait!
LED:
3 seconds
Signal:
yellow steady signal
Meaning:
During start-up when
radio button is pressed
LED:
1 second
Signal:
long yellow intervals
(slow)
Meaning:
Networking mode
(for approx. 10 minutes)
LED:
3 seconds
Signal:
green steady signal
Meaning:
An action has been
completed successfully
LED:
3 seconds
Signal:
red steady signal
Meaning:
Error
CHOOSING A LOCATION (acc. DIN 14676)
Fig. 2
RM
Bedroom
RM
RM
Children's
room
Living room
RM
RM
RM
Kitchen
RM
Boiler /
utility room
RM
RM
Workshop
RM
RM
Bedroom
Bath
Kitchen
RM
RM
RM
RM
Childrens
Childrens
Living room
room
room
at least
optimal
RM
RM
- Do not install in environments that
are subject to drafts (e.g. fan,
ventilation...) or bathrooms
- Unit is suitable for kitchens, if false
alarms due to steam can be ruled
out
– 40 –
- At the highest installation position
on the ceiling in the middle of the
room (not on walls )
- Minimum distance of 50 cm from
walls, furniture, lamps
- Monitored area maximum 60 m
with maximum ceiling height of 6 m
- Distance between two devices
maximum 15 m
- Corridor length maximum 7,5 m
RM
- Not onto the ceiling beam for ceiling
beams with a height of >20 cm, but
1 device per intermediate space up
to a maximum of 36 m
area
- For ceiling beams with a height of
<20 cm, a detector at the centre of
RM
the room (also possible on ceiling
beam)
- Platforms/galleries <16 m
least 2 m long and wide: 1 detector
• over 16 m
: install additional
2
detectors
- Roof slopes (slopes below 20° are
considered flat ceilings):
In the event of a fire, this device
quickly detects the build-up of smoke
and also the associated rise in
temperature in the room. In order to
warn you in good time, it then emits
a loud alarm sound. If you decide
that there is no real need to escape
the building you can temporarily
deactivate this signal (for approx. 10
minutes), or temporarily disable it
before sounding, by gently pressing
the Test/Stop button (Fig. 1, IV). We
2
recommend that you then provide
good ventilation to the room to pre-
vent the alarm being triggered again.
in surface
2
> 20°
and at
2
> 20°
> 20°
– 41 –
GB
> 1.00
1/2
1/2
< 1.00