the tank.
Regularly drain off condensate collecting in the
water trap.
7.1.2 After slaughtering
At the end of the shift, disconnect the device
from the compressed air system (see chapter
3.1.5 "Disconnecting the stunning device" (page
4)).
Apply a little oil to the moving parts (release
valve (18), safety switch (55) and rocker (22),
see Anhang A.1.1 (S. 11) and Appendix A.1.2
(page 11)) and check for easy movement.
Caution! Ensure that no water enters the device
through the vent slots (see Appendix A.1.1 (page
11)).
7.1.3 Wear
Check the buffers (49 and 49a) after approx.
50,000 stunning processes and replace, if there
is any damage!
7.1.4 Compressed air motor and gear system
Every 3 months, clean the unit completely and
replace all worn and/or defective parts.
7.1.5 Maintenance unit
Regularly (minimum 2x per month) inspect the
maintenance unit, drain off the condensate and
add special oil.
Special oil for maintenance unit:
EFA special oil 0.5 l, prod. no. 001 365 611
EFA special oil 5.0 l, prod. no. 001 365 612
Special oil for compressor:
EFA special oil 1.0 l, prod. no. 001 365 637
EFA special oil 5.0 l, prod. no. 001 365 636
Schmid & Wezel
D 75433 Maulbronn
7.2 Repair
All repairs must be completed by
authorised specialist technicians.
Before carrying out any repair
work, switch off the stunning
device and disconnect it from the
compressed air supply line.
Use only original spare parts.
Important instructions:
For spare parts lists, see Appendix 3
(page 13).
On request, we supply spare parts lists
for repair workshops.
7.3 Storage of stunning device
Store the stunning device in a dry room.
8. Return of decommissioned
equipment
For proper disposal, return your equipment to
Schmid & Wezel.