Herunterladen Diese Seite drucken

HTS ECO-Jack EJ30-5S Originalbetriebsanleitung Seite 16

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN | English
WARNING
Warning against bruising
Keep body parts away from lifted
loads and movable parts.
Never put body parts, such as hands, feet,
arms, head etc. under the load.
Limbs may be crushed when lowering the load.
If the device is blocked the operator must lift the load with
another jack until the blocked lifter is released and can be moved.
Emergency procedure: Conduct a first-aid procedure
adequate to the injury and summon qualified medical
attendance as quickly as possible. Protect the injured
person from further harm and calm them down.
Storage and transport
Use appropriate lifting equipment for transportation.
The appliance must be stored in a dry
place and protected from frost.
Lock the device in a proper place to protect
it from unauthorised use.
Maintenance
Ensure that the warning signs are always in good working order.
Accident prevention regulation (APR): Have an expert
check the equipment at least once a year.
Have your device repaired only by qualified professional
staff using original spare parts. This will ensure that
the safety of the power tool is maintained.
Insufficient maintenance and care can lead to
unforeseen accidents and injuries.
Keep the apparatus handle clean, dry and free of spilt oil or grease.
Never clean the machine and its components with solvents,
flammable or toxic liquids. Us only a damp cloth making. 
If needed, an exploded view of the tool can be ordered.
Please state the ten-digit No. as well as the machine type
printed on the label and order the drawing at HTS.
Disposal
Any damaged or disposed devices must be
delivered to appropriate collection centres.
Never dispose of oils, fuel or other polluting
materials in unauthorised places. Make sure
the oil products do not enter the soil.
Guarantee
Warranty period of 12 months applies to commercial use
and commences on the day of purchase of the device.
The guarantee does not cover any unauthorised use such as
appliance overloading, use of violence, damage as a result
Failure removal
Failures
Causes
Load is only
Lack of oil
partially lifted
Load is not lifted
Discharge valve open
Lifting force is insufficient
The valve is loose
The ball seat of the discharge valve is not tight
Safety valve defective or dirty
Air in the hydraulic system
Sleeve button defect
Load sinks down (with
Safety valve defective or dirty
closed discharge valve)
Nut ring defect
16
of any unauthorised interference or caused by foreign items.
Failing to follow the operating and assembly instructions
and common wear are also not included in the guarantee.
EC Declaration Of Conformity
We declare under our sole responsibility that the Hydraulic Toe
Jack HTS ECO-Jack®, to which this declaration relates correspond
to the relevant basic safety and health requirements of Directives
2006/42/EC Machinery Directive including amendments.
The applied standards and EC and UK guidelines
can be found on the test certificate that is
included with each supplied product.
CE marking
Fellbach, 2021-09-13
Michael Koch / Managing Director
Maintenance of technical documentation:
HTS GmbH
Ringstr. 28, 70736 Fellbach, Germany
UK Declaration Of Conformity
We declare under our sole responsibility that the Hydraulic Toe
Jack HTS ECO-Jack®, to which this declaration relates correspond
to the relevant basic safety and health requirements of Directives
Machinery Directive including amendments S.I. 2008/1597
The Supply of Machinery (Safety) Regulations 2008.
The applied standards and EC and UK guidelines
can be found on the test certificate that is
included with each supplied product.
British Conformity Mark
Fellbach, 2021-09-13
Michael Koch / Managing Director
Maintenance of technical documentation:
HTS Direct Limited
Unit 18, Emerald Way, Stone Business Park,
Stone, Staffordshire, ST15 0SR
Removal
Refill oil
Close
Use an additional or a more powerful ECO-Jack
Tighten the threaded insert for pump tappet
Push in the valve seat again. Screw the valve
screws very tightly (use pliers if required)
Remove, Clean
Vent all lines of the lifter by repeated rapid blowback
and blowout of the lifter and vent the nipples as well
Remove, Renew
Remove, Clean / Renew
Remove, Renew