The duty cycle menu allows you to adjust the duty cycle value as well as the duty cycle units. To
adjust the duty cycle value, select "Pulse" by means of the Up/Down keys and press OK. Once
OK has been pressed, the number can be modified digit by digit.
Figure 37. Duty Cycle - modify value
To increase/decrease the highlighted digit, use the Up/Down keys and to move to the
next/previous digit, use the Right/Left keys. Once the desired value has been entered, press the
OK key and the flashing duty cycle will be set. A longer flash duration increases the light intensity
of the flash.
To modify the duty cycle unit, select "Units", using the Up/Down keys. Once the line is highlighted,
press OK and a submenu will be displayed.
Figure 38. Duty Cycle - Units
An orange tick can be found next to the duty cycle unit the device is using at the moment. Use
the Up/Down keys to select the desired unit (percentage, degree or time) and press OK to set the
unit.
You can go back to the duty cycle menu by pressing the Back key. To go directly to the main
screen, press the Quick key.
© PCE Instruments