Preflow Time
shielding gas flows after the trigger is
pulled and prior to feeding.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Postflow Time
shielding gas flows after the welding output
turns off.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Burnback Time is the amount of time that
the weld output continues after the wire
stops feeding. It prevents the wire from
sticking in the puddle and prepares the end of the wire
for the next arc start.
Adjust range: from OFF to 0.25 seconds (factory
default is set at Auto mode).
Spot Timer– adjusts the time welding will
continue even if the trigger is still pulled.
This option has no effect in 4-Step Trigger
Mode.
Adjust range: from 0 second (OFF) to 120 seconds
(factory default is OFF).
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Run-in WFS – sets the wire feed speed
from the time the trigger is pulled until an arc
is established.
Adjust range: from minimum to maximum WFS
(factory default is set at Auto mode).
The Start Procedure
and Volts (or Trim) for a specified time at the
beginning of the weld. During the start time,
the machine will ramp up or down from the
Start Procedure to the preset Welding Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
Crater Procedure – controls the WFS (or
value in ampere units) and Volts (or Trim) for
a specified time at the end of the weld after
the trigger is released. During the Crater time, the
machine will ramp up or down from the Weld Procedure
to the Crater Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
A/B procedure – enables quick weld
procedure change. The sequence changes
may occur between:
Two different welding programs.
Different settings for the same program.
English
adjusts the time that
adjusts the time that
controls the WFS
Save Memory: Store the welding programs
with their parameters to one of the fifty user
Memories.
To save memory:
Add Save Memory icon to Welding Parameters Bar.
Use the Right Knob [36] to highlight the icon Save
Memory.
Press the Right Knob [36] to confirm – the Save
Memory Menu is shown on the display .
Use the Right Knob to highlight the memory number
where the program would be stored.
Confirm the selection – Press and hold for 3 second
Right Knob [36].
Rename job – turn Right Knob [36] to select:
numbers 0-9, letters A-Z, a-z. Press Right Knob [36]
to confirm first character of the name.
Next characters are selected in the same.
To confirm the name of job and back to the main
menu press Button [37] or Left Knob [35].