Herunterladen Diese Seite drucken

Lincoln Electric OERLIKON CITOSTEEL 255C Bedienungsanleitung Seite 14

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 86
10. Power Lead (5m): Connect the supply plug to the
existing input cable that is rated for the machine as
indicated in this manual, and conforms to all
applicable standards. This connection shall be
performed by a qualified person only.
11. Supply
Plug:
For
"Accessories" chapter).
12. Gas Connector: Connection for gas line.
13. Gas Flow Regulator Plug: Gas flow regulator can be
purchased separately (see "Accessories" chapter).
14. Gas hose
15. Work Lead
Internal Controls
Figure 4.
16. Spooled Wire (for GMAW / FCAW): The machine
does not include a spooled wire.
17. Wire Spool Support: Maximum 16kg spools. Accepts
plastic, steel and fiber spools onto 51 mm spindle.
Note: Plastic Brake Nut has a Left-hand thread.
18. Cold Inch/ Gas Purge Switch: This switch enables
wire feeding or gas flow without turning on output
voltage.
19. Wire
drive
feeding
mechanisms with quick-change feed rolls.
20. Terminal Block of Changing Polarity Plug (for GMAW /
FCAW-SS process): This terminal block enables to
set the welding polarity (+ ; -), which will be given at
the welding gun (see "Accessories" chapter).
21a. USB Receptacle Type A (PRO only):
For USB memory stick connection. For machine
software update and service purpose.
21b. Fuse F1:
Use the 1A/400V (6,3x32mm) low blow fuse.
English
CO2
gas
heater
kit
system:
4-Roll
wire
Basic User Interface (U0)
(see
22. Display:
Left display: Shows wire feed speed or welding
current. During welding shows the actual welding
current value.
Right display: Shows the welding voltage in volts
units. During welding shows the actual welding
voltage value.
23. Right Control: Adjusts values on the Right display.
24. Left Control: Adjusts values on the Left display.
25. Right Button: Enables scrolling, changing and setting
welding parameters.
26. Left Button: Enables changing the welding process.
27. Thermal Overload Indicator: It indicates that the
machine is overloaded or that the cooling is not
sufficient.
28. Status LED: A two color light that indicates system
errors. Normal operation is steady green light. Error
drive
conditions are indicated, per Table 1.
The status light will flash green, and sometimes red and
green, for up to one minute when the machine is first
turned on. When the power source is powered it can take
as long as 60 seconds for the machine to be ready to
weld. This is a normal situation as the machine goes
through initialization.
10
Figure 5.
WARNING
English

Werbung

loading