DISPLAY PROGRAMMING
After setting parameter of time press again key "OK" to confirm and exit. To exit from
programme menu press "ESC".
WEAR GRINDERS - Provides information on the total doses that can be erogated before
the replacement of the grinders. This item is editable. press for 3 seconds key "MENU" to
get access to programme menu. press the key "+" or "-" to slide the menu options, select
"WEAR GRINDERS" pressing key "OK".
Using key "+" or "-" it's possible to increase or decrease the dosis. press key "OK" to
confirm and exit. To exit from programme menu press "ESC".
Upon reaching the maximum doses that can be erogated with the set of grinders in use, the
display will show the written "WEAR GRINDERS". When replacing the grinders, enter the
general programming menu and access "DISPENSED DOSES TOTAL COUNT". Press key
"RESET" to carry back the number as the value of "WEAR GRINDERS". After doing it, the
written "WEAR GRINDERS" will disappear from the display. To exit from programme menu
press "ESC".
SET WRITTEN "READY" - Keep touched for 3 seconds key "MENU" to get access
to programme menu. press the key "+" or "-" to slide the menu options, select "BAR
message". Select it pressing key "OK", then using key "MAN" move the cursor till the point
you want the written begins. Use key "+" and "-" to slide the alphanumeric list; to stop
at choosen character and move to next, use key "MAN". Repeat the procedure till the
choosen code for stand by mode is complete. To confirm and exit press "OK". To exit from
programme menu press "ESC".
BRIGHTNESS - To set the display brightness. press for 3 seconds key "MENU" to get access
to programme menu. Press the key "+" or "-" to slide the menu options, select "brightness"
pressing key "OK", then using "+" or "-" it's possible to increase or decrease the brightness
from 0 to100%. To confirm and exit press "OK". To exit from programme menu press
"ESC".
TOTAL COUNT OF EROGATED DOSES - Provides information on the total doses
erogated by the grinder and the remanent doses until the next grinding blades change. To
display it, press for 3 seconds key "MENU" to get access to programme menu.