OPERATION
PARTIAL COUNT OF DISPENSED DOSES - Provides the amount of doses dispensed
since the last reset (usually to account for doses dispensed throughout the day/week).
To reset, press the 'MENU' button for 3 seconds to access the programming menu, press
'+' or '-' to scroll through the menu until you reach the message: 'partial count'. Select it
by pressing 'OK'. At this point, press and hold the 'RESET' button until the displayed digit
returns to zero. To confirm and exit, press 'OK'. Exit the menu by pressing 'ESC'.
MONTHLY COUNT OF DISPENSED DOSES - Provides the amount of doses dispen-
sed since the last reset (usually to account for doses dispensed since the beginning of
the month), plus previous doses, automatically resetting to zero after 3 days. To reset,
press the 'MENU' button for 3 seconds to access the programming menu, press '+' or
'-' to scroll through the menu until you reach the message: 'monthly count'. Select it by
tapping 'OK'. At this point, press and hold the 'RESET' button until the displayed digit
returns to zero.
To confirm and exit, press 'OK'. To exit the menu, press 'ESC'.
CHANGE LANGUAGE - Press the 'change language' button for 3 seconds: select it by
tapping the 'OK' button, then use '+' or '-' to scroll through the available languages. Once
the desired one has been found, press the 'OK' button again to confirm and exit. To exit
the menu, press 'ESC'.
SETUP PASSWORD - Sets the password for using the MENU. The password is numeric,
consisting of five digits definable from 0 to 9. Press the 'MENU' button for 3 seconds to
access the programming menu, press the '+' or '-' button to scroll through the menu until
you reach the message 'SETUP PASSWORD': select it by tapping the 'OK' button. To set
the password: use the '+' and '-' keys to scroll to the desired number. Press the 'MAN'
button to move to the next digit. Once the password has been defined, press the 'OK'
button to confirm and exit. To exit the menu, press 'ESC'.
OPTION PASSWORD - Enables or disables the use of the password to access the
'MENU'.
IMPORTANT NOTE: CAUTION - The default password is 12345.
Stand-by consumption: 1.1 W.
Q50 ELECTRONIC VERSION:
Caution: To stop dispensing, press any of the 4 buttons on the display.
Operation and programming:
1. Operation: before plugging in the mains, check that the switch is set to 'O'. Insert the
hopper locking tab and check that it slides into place.
Place the hopper in its seat by applying pressure to the side with your fingers until it is
firmly in place, then attach it to the grinding adjustment ring nut using the specific screw
supplied with the appliance, making sure that the hole on the hopper is aligned with the
one on the ring nut.
34