Sensor: Selection of the exact type of Intelligent Battery Sensor.
Battery Type: Selection of the fitting battery type. (Gel, AGM or Flooded)
Capacity: Type in the capacity of the battery. The number can be found written on the battery. On a battery
pack, add up these numbers of the different batteries.
BRIGHTNESS AND CLOCK
To change these parameters, open the tab "Settings".
Illumination: Use the sliders to define the brightness levels for the day and night mode.
The day or night mode depends on the applied signal on the illumination input (Pin 6 – Red/White).
Clock Offset: The time is not counted internally but can only be received via NMEA 2000.
On NMEA 2000 only the UTC+00:00 time is sent. This means, the device must be configured to match the
time in your current time zone. To do so select the according offset in this menu.
Clock Format: Select whether the time should be displayed in a 12h or 24h format.
SUPPORTED CONFIGURATIONS
Display type
Tachometer
Boat speed
Ammeter
Voltmeter
Battery charge
Battery status
Battery temperature
Battery autonomy
Operating hours
14
Resistive
Unit
Sensor
rpm
-
kn
km/h
-
mph
A
-
V
-
%
-
%
-
°C
-
°F
h
-
days
h
-
Frequency
Calibrations
Sensor
Pulses per
revolution
Pulses per unit
-
Measures supply
-
voltage
-
-
-
-
Calculated
internally
CONFIGURATION
Alarm
available
No
No
-
No
No
Yes
-
(below)
Yes
-
(below)
Yes
-
(above)
-
No
No
PGN
127488
128259
127508
127508
127506
127506
127508
127506
127489
B000882