NMEA 2000® PINOUT
Pin no.
Description
1
-
2
-
3
-
4
NET-H (CAN High)
5
NET-L (CAN Low)
CONNECTION TO THE NMEA 2000® NETWORK
Once mounting is complete, the device can be connected to the NMEA
2000® network via the designated socket on the cabling.
Ensure to tighten the M12 connector by screwing it onto its counterpart, so
to preserve water tightness.
A drop cable is only required if the total length of the supplied cabling is
not sufficient to reach the NMEA 2000® backbone.
Note that NMEA 2000® does not allow drop cables longer than 6 meters.
Stick to the NMEA 2000® standard for proper network setup.
CONNECTION TO THE IBS
IBS-Connector:
1: Supply Voltage
2: LIN
Remove the whole system from the negative pole of the battery and install the IBS on the pole instead.
Reattach the system's main ground connection on the IBS' pole adapter. Do not connect anything directly
to the negative battery pole, as any current not going through the sensor will not be measured and will
corrupt the calculations of the SOC and SOH.
Mind the pinouts stated above, to connect the LIN bus.
10
CONNECTIONS
Micro-C M12 5-pin connector
Male, Cable View
B000882