Herunterladen Diese Seite drucken

CHAUFFAGE FRANCAIS Stelios 250 L Benutzerhandbuch Seite 58

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 66
for 3 seconds, it is unlocked, the
To relock the control panel, press the
Without actions on the control panel for 3 minutes, the screen will re-lock automatically.
9. Screen timeout
When the device is stopped and without defects, without action on the control panel for 60
seconds, the screen goes to sleep.
Press any key to exit standby mode.
10. Sound
When the device is started, the speaker emits a sound.
Pressing a button makes a noise.
When the system is faulty, no sound is emitted.
11. Special operation
1) Anti Legionella
The anti-legionella cycle can be 26activated or deactivated on the control panel, by default it is
deactivated, refer to the table of configuration parameters. When the anti-legionella function is
26activated, the water temperature set point is set to 70℃, it displays H1 in the display area (always
bright), the clock area displays the current temperature of the sanitary 26balloon.
Factory setting:
a. On power-up or after an anti-legionella cycle carried out since 168H, the water is not heated to
70°C
b. Time displayed 2:00.
c. Water temperature ≤68℃.
d. No error in progress.
Note: All conditions must be met to trigger the anti-legionella cycle.
Stopping the anti-legionella cycle:
a. Sanitary Water Temperature >70℃.
b. Devices in fault.
c. Faulty Sanitary Water temperature probe.
d. Action on the button
Note: Fulfil any of the conditions a, c, d, the anti-legionella cycle stops. If condition b is met, the
anti-legionella cycle is continued by the electrical resistance.
2) Antifreeze function:
icon is extinguished.
button for 3 seconds and the
.
icon will light up.