(2) Power specifications
Power
Neutral wire/Phase
220-240VAC~
50Hz
8.
Commissioning
(1) Before commissioning
The appliance must be installed and connected correctly
Piping and wiring must be correct
The supply voltage must correspond to the nominal voltage.
The wastewater evacuation must work properly.
The insulation must be completed.
The earth wire must be correctly connected.
The air inlet and outlet orifices should not be obstructed.
The water heater must be filled with water.
(2) Live operation
Make sure that all control buttons are functional.
Check if the hot water system is working correctly and if the outlet water temperature is normal.
When the safety valve is operating, check that it can evacuate water.
Check that there are no abnormal vibrations or noises during the operation of the device
Power cord diameter
(mm2)
wire
(Length ≤ 30m)
≥1.5
Hand switch
(A)
Earthing
Capacity
wire
≥1.5
20
Earth leak circuit
breaker
Fuse
30mA
15
30mA, below 0.1 sec
.

Werbung