7.
Electrical wiring
The appliance must use the specified power cord, which must comply with the table below. The supply
voltage must also correspond to the required nominal voltage.
The power circuit must be equipped with an earth wire, which must be connected to the external earth
effectively.
The connection of the cables must be carried out by a professional technician in strict compliance with
the electrical diagram.
Put in place an earth leakage protection in accordance with the standards in force applicable to electrical
equipment.
Use an omnipolar disconnection device with a contact separation of at least 3 mm when connecting the
power supply.
Check the electrical circuit twice before connecting it to the electrical supply.
Do not disconnect or cut the earth wire, and do not use broken cables or switches in any way. If you
notice a break, the power cord must be replaced as soon as possible.
(1) Earth leak circuit breaker protection
Fig.7 Earth leakage protection