Initial startup
WARNING
Potential equalisation line not connect-
ed correctly
Electric shock
Every time before use, check whether the
equipotential bonding conductor (earthing
conductors) are connected.
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Do not vacuum without correctly installed
filter elements, otherwise a danger to
health from increased fine dust emission is
present.
ATTENTION
Missing filter element
Damage to the suction motor
Do not vacuum without a filter element.
1. Bring the device into the working posi-
tion.
2. Secure the device with the parking
brakes.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose (not included in
the scope of delivery) into the suction
connection.
5. Check the filling level in the dirt recepta-
cle (see chapter Check the dirt recepta-
cle filling level).
6. Empty the dirt receptacle if necessary
(see chapter Emptying the dirt recepta-
cle).
7. Fit the dust bag before dry vacuuming
(see chapter Fitting the dust bag).
Illustration B
8. Fit the desired accessory (not included
in the scope of delivery) onto the suction
hose.
Closing the suction connection
WARNING
Risk of injury
Damage to the skin, lungs and eyes
through fine dust
The suction connection must be closed us-
ing the sealing plug after removing the suc-
tion hose.
1. Remove the suction hose.
Illustration C
2. Insert the sealing plug precisely into the
suction connection.
3. Push the sealing plug in all the way to
the end stop.
4. Turn the sealing plug to the right until the
suction connection is tightly closed.
Check the dirt receptacle filling level
The dirt receptacle must be emptied when
filled to the lower edge of the suction hose
port on the dirt receptacle. The device does
not switch off automatically if the maximum
filling level is exceeded.
1. Check the dirt receptacle filling level reg-
ularly.
The device is suitable for vacuuming fine
dust up to dust class M.
WARNING
Danger from dust that is harmful to your
health
Respiratory sicknesses through inhalation
of dust.
Do not vacuum without correctly installed
filter elements, otherwise a danger to
health from increased fine dust emission is
present.
ATTENTION
Danger due to fine dust entering
Risk of damage to the suction motor.
Never remove the filter element when vac-
uuming.
Fitting the dust bag
1. Secure the device with the parking
brakes.
2. Disconnect the pressure equalisation
hose from the dirt receptacle.
Illustration D
3. Lower the dirt receptacle by pulling up
the lever.
Illustration E
4. Pull the dirt receptacle out of the device.
English