BD Sensors AX18-DPT200 Betriebsanleitung Seite 38

Differenz-druckmessumformer für die prozessindustrie
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
DGP 100
Pressure range gauge
Sensor
Pressure range dp
Setting limits
(offset and span in this range
freely adjustable)
Lowest permissible span
Overcharge
Burst pressure
rangeability TD
(with respect to the differen-
tial pressure range dp)
Pressure range abs.
Sensor
Pressure range P
N
Setting limits
(offset and span in this range
freely adjustable)
Lowest permissible span
Overcharge
Burst pressure ≥
Rangeability TD
(with respect to the differential
pressure range dp)
Output signal / Supply
Standard
Signal range
Error signal
Performance
Accuracy
Influence supply
Influence installation position
Long term stability
Permissible load
Response time T90
damping
Thermal effects (Offset and Span)
Temperature range -40 ... 100°C
Permissible temperatures
Environment / storage
Media wetted parts
B
C
Type
0.06
0.4
[bar]
-0.06 ...
-0.4 ... 0.4
0.06
6 mbar
20 mbar
2
10
[bar]
3
11
[bar]
10:1
20:1
L
Type
0.4
[bar]
0 ... 4
20 mbar
10
[bar]
11
[bar]
20:1
2-wires: 4 ... 20 mA / U
(with LCD-Display
3.9 ... 20.5 mA
Low: 3.7 mA / High 21 mA (standard)
TD ≤ 10:1:
≤ ± 0.075 % FSO
≤ ± [0.0075x TD] % FSO
TD >10:1:
(TD = pressure range P
(FSO = Full Scale Output)
≤ 0,001 % FSO / 10 V
max. 250 Pa (can be compensated about zero-point correction)
≤ ± (0.2% x pressure range P
Type B/L:
≤ ± (0.1% x pressure range P
other:
without LCD-display : R
with LCD-display
-communication: R = 230 Ω ... 600 Ω
®
HART
Type B: ca. 0.35s
Type C: ca. 0.25s
electronic : 0 ... 60 s plus response time T90
Type B/L:
± [0.30 x TD + 0.20]% of the adjusted range
other:
± [0.20 x TD + 0.10]% of the adjusted range
without display
: -40 ... 85 °C
with display
: -20 ... 65 °C
Silicon oil
: -40 ... 100 °C
D
F
2.5
30
-1 ... 2.5
-1 ... 30
-1 ... 100
25 mbar
300 mbar
40
150
41
160
100:1
100:1
M
2.5
0 ... 2,5
25 mbar
40
41
100:1
= 12 ... 42 V
B
DC
/ U
= 15 ... 42 V
)
B
DC
/ adjusted range)
N
) / year
N
) / year
N
– 12 V) / 0.023 A] Ω
= [(U
max
B
– 15 V) / 0.023 A] Ω
: R
= [(U
max
B
Type D - O: ca. 0.15s
(85°C without function)
(Info: +125°C short time, max. 30 min.)
G
H
I
100
210
400
-1 ... 210
-1 ... 400
1 bar
2.1 bar
4 bar
200
500
500
210
710
710
100:1
100:1
100:1
30 bar
0...30
300 mbar
100:1
J
600
-1 ... 600
0...6 bar
700
710
100:1
O
150
160