BD Sensors AX18-DPT200 Betriebsanleitung Seite 36

Differenz-druckmessumformer für die prozessindustrie
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
DGP 200
Pressure range gauge
Sensor
Pressure range dp
Setting limits
(offset and span in this range
freely adjustable)
Lowest permissible span
Overcharge
Burst pressure ≥
rangeability TD
(with respect to the differential
pressure range dp)
Pressure range abs.
Sensor
Pressure range P
N
Setting limits
(offset and span in this range
freely adjustable)
Lowest permissible span
Overcharge
Burst pressure
rangeability TD
(with respect to the differential
pressure range dp)
Output signal / Supply
Standard
Signal range
Error signal
Performance
Accuracy
Influence supply
Influence installation position
Long term stability
Permissible load
Response time T90 (t.b.d.)
damping
Thermal effects (Offset and Span)
Temperature range -40 ... 100°C
Permissible temperatures
Environment / storage
Media wetted parts
1B
1C
Type
0.06
0.4
[bar]
-0.06 ... 0.06
-0.4 ... 0.4
0...6 mbar
0...20 mbar
400
400
[bar]
-
-
[bar]
10:1
20:1
1L
Type
0.4
[bar]
0 ... 4
0...20 mbar
10
[bar]
11
[bar]
20:1
2-wires: 4 ... 20 mA / U
(with LCD-Display
3.9 ... 20.5 mA
Low: 3.7 mA / High: 21 mA (standard)
TD ≤ 10:1:
≤ ± 0.075 % FSO
≤ ± [0.0075x TD] % FSO
TD >10:1:
(TD = pressure range P
(FSO = Full Scale Output)
≤ 0.001 % FSO / 10 V
max. 400 Pa (can be compensated about zero-point correction)
Type 1B/1L: ≤ ± (0.2% x pressure range P
≤ ± (0.1% x pressure range P
andere:
without LCD-display : R
with LCD-display
: R
®
-communication: R = 230 Ω ... 600 Ω
HART
Typee 1B: ca. 0.4s
Type 1C: ca. 0.2s
Type 1D: ca. 0.2s
electronic : 0 ... 60 s plus response time T90
Type 1B/1L: ± [0.30 x TD + 0.20]% of the adjusted range
other:
± [0.20 x TD + 0.10]% of the adjusted range
without display
: -40 ... 85 °C
with display
: -20 ... 65 °C
Silicon oil
: -40 ... 100 °C
1D
1E
2.5
20
-1 ... 2.5
-1 ... 20
0...25 mbar
0...200 mbar
400
400
-
-
100:1
100:1
1M
2.5
0 ... 2,5
0...25 mbar
40
41
100:1
= 12 ... 42 V
B
DC
/ U
= 15 ... 42 V
)
B
DC
/ adjusted range)
N
) / year
N
) / year
N
– 12 V) / 0.023 A] Ω
= [(U
max
B
– 15 V) / 0.023 A] Ω
= [(U
max
B
Typee 1E – 1O: ca. 0.1s
(85°C without function)
(Info: +125°C short time, max. 30 min.)
1G
1H
100
210
-1 ... 100
-1 ... 210
-1 ... 400
0...1 bar
0...2.1 bar
0...4 bar
200
500
210
710
100:1
100:1
1O
30 bar
0...30
0...300 mbar
150
160
100:1
1I
400
500
710
100:1