P2: Time format
Parameter P2 allows you to specify whether the time is dis-
played in the 12 hour or 24 hour format.
P3: Units for temperature indication
Parameter P3 is used to specify whether the room temperature
is displayed in degrees Celsius [°C] or Fahrenheit [°F].
P4: Reset time programs
Activating parameter P4 resets all time programs to the factory
setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
9
Cleaning (users)
Property damage
If moisture enters the appliance, the electronic com-
ponents may be damaged.
u Never spray cleaning spray into the air slot.
u Ensure that no moisture can enter the appliance.
u If a pale brownish discolouration appears on the appliance
casing, wipe it off with a damp cloth.
u Clean the appliance when cold with ordinary cleaning
products. Avoid abrasive or corrosive cleaning products.
10 Troubleshooting (users)
Fault
Possible cause
Room does not get
Temperature set too
warm enough. Ap-
low on the appli-
pliance does not get
ance.
hot.
No power supply.
Room does not get
Overheating. The
warm enough al-
high limit safety cut-
though the appli-
out limits the heat-
ance is hot.
ing output.
Heat demand of the
room is higher than
the appliance out-
put.
The room gets too
Appliance temperat-
hot.
ure is set too high.
Detected room tem-
perature does not
match actual room
temperature.
www.stiebel-eltron.com
NOTICE
Remedy
Check the selected
room temperature.
Adjust if necessary.
Check position of the
ON/OFF switch, RCD
and fuse/MCB in
your fuse box.
Eliminate the cause
(dirt or obstructions
at the air intake or
outlet). Observe the
minimum clear-
ances.
Remedy heat losses
(close windows and
doors; avoid con-
stant airing).
Check the selected
room temperature.
Adjust if necessary.
Avoid obstructions
to air flow between
appliance and in-
door air.
Fault
Possible cause
Window-open de-
Appliance does not
tection does not re-
detect a pronounced
spond.
temperature drop
when airing. (Win-
dow-open detection
requires a previ-
ously stable room
temperature.)
Window-open de-
tection is not en-
abled.
"Adaptive start"
This function is only
function does not
effective when a
work as required.
time program is act-
ive.
Severely fluctuating
room temperature
or the appliance
learning procedure
has not been com-
pleted.
"Adaptive start"
function is not en-
abled.
The display shows
Internal fault detec-
"Err" or "E...".
ted.
u If you cannot remedy the fault, contact your qualified con-
tractor.
u To facilitate and speed up your enquiry, please provide the
qualified contractor with the number from the type plate.
11 Troubleshooting (qualified con-
tractors)
To prevent hazards, the power cable must only be replaced (for
example if damaged) by a qualified contractor authorised by the
manufacturer, using an original spare part.
12 Removal
u Undo and remove the locking screw from the wall mounting
bracket.
u To release the appliance, push down the springs at the top
of the wall mounting bracket.
u Tilt the appliance forwards.
u Lift the appliance off the bottom tabs on the wall mounting
bracket.
13 Specification
13.1 Dimensions and connections
Cleaning (users)
Remedy
After making set-
tings on the appli-
ance, wait a while
until the room tem-
perature has fully
stabilised.
Avoid obstructions
to air flow between
appliance and in-
door air.
Manually switch the
appliance to standby
while windows are
open.
Switch on window-
open detection in
the standard menu.
Use the time pro-
grams for optimised
heating conveni-
ence.
Wait a few days for
the behaviour to
stabilise.
Switch on the "Ad-
aptive start" function
in the standard
menu.
Notify a qualified
contractor.
|