Installation (qualified contractors)
The air inside the appliance is heated by a heating element and
expelled via natural convection through the air discharge at the
top. Cool indoor air is drawn in through the air intake on the
underside of the appliance. When the set room temperature is
reached, it is maintained by periodic heating.
4.1
Standard delivery
– 1x wall mounting bracket (hooked into the appliance)
5
Installation (qualified contractors)
5.1
Installation site
CAUTION
Burns
u Only mount the appliance on a vertical wall that
is temperature-resistant to at least 85 °C.
Property damage
u Never install the appliance directly below a wall
socket.
u Ensure that the power cable is not in contact with
any appliance components.
5.1.1 Installation in bathrooms
WARNING
Electrocution
When installing the appliance in rooms with a bath
and/or shower, the appliance must only be connected
to a standard safety socket outside safety zones 0, 1
and 2. The standard safety socket must be at least
600 mm away from a bath or shower. If in doubt, con-
sult a qualified contractor.
Property damage
If installing the appliance in a bathroom, it must only
be installed a sufficient distance away from a bathtub
and/or shower. If water gets into electronic compon-
ents and enclosures, a short circuit may occur or the
appliance may be damaged.
u During installation, ensure that switches and
other operating controls of the appliance cannot
be touched by people who are in the bath or
shower.
18
|
NOTICE
NOTICE
3
D0000097137
Electrical safety zones in the bathroom
5.1.2 Minimum clearances
≥100
D0000112446
≥224
D0000112447
5.2
Installing the wall mounting bracket
The appliance is intended for wall mounting using the wall
mounting bracket supplied.
u Only mount the appliance horizontally on the
wall.
u The wall mounting bracket can be used as a
template for wall mounting. This ensures suffi-
cient clearance from the floor.
u Unhook the wall mounting bracket from the appliance.
u Place the wall retainer horizontally on the floor. Use a spirit
level if the floor is uneven or sloping.
1
0
2
≥100
≥500
≥20
≥224
www.stiebel-eltron.com