Symbols Description
Window-open detection:
To avoid unnecessary energy consumption while air-
ing the room, the appliance automatically switches to
frost protection mode for one hour if a window is
opened. The "Window-open detection" symbol
flashes. After airing, frost protection mode can be ter-
minated manually by pressing "+". The appliance
then heats to the set room temperature again.
Requirement: window-open detection is enabled (see
chapter Standard menu [} 21] ).
Operating lock:
To lock or unlock the operating buttons, press "+" and
"–" simultaneously for 5 seconds.
Heating enabled:
The appliance is heating to maintain the set room
temperature.
Room temperature indication
Editable parameter:
The parameter shown can be changed using "+" and
"–".
Days of the week:
1 = Monday, 2 = Tuesday ... 7 = Sunday
7.5
Standby
Property damage
In standby mode, the appliance will not switch on the
heating. There will be no frost protection.
u To switch on the programming unit, press "Standby".
ð The default display appears.
u To put the programming unit and the heating appliance
into standby, press "Standby".
ð The display shows "- - - -".
8
Settings
8.1
Default display
D0000072134
The default display is displayed continuously. If no user input is
made for more than 20  seconds while in the menu, the device
automatically returns the default display.
The default display shows the current set room temperature as
well as the "Editable parameter" symbol.
u Use "+" and "–" to select the set room temperature.
If the set room temperature corresponds to one of the values set
for the comfort or setback temperature, the symbol for the cor-
responding operating mode (comfort mode, setback mode) ap-
pears in the menu bar.
The set room temperature can be changed manually when a
time program is active. The new set room temperature is main-
tained until the next programmed switching point is reached.
www.stiebel-eltron.com
NOTICE
8.2
Standard menu
u To call up the standard menu, briefly press "Menu".
Menu items
Display
Description
To select the day of the week and time:
Days of the week: 1 = Monday to 7 = Sunday
To set the comfort temperature:
The comfort temperature must be set at least
0.5 °C higher than the setback temperature.
To set the setback temperature:
The setback temperature must be set at least
0.5 °C lower than the comfort temperature.
To switch "Window-open detection" function on
and off
Select or deactivate (off) the time program (Pro1,
Pro2, Pro3)
To switch "Adaptive start" function on and off
Changing the menu item settings
u Call up the required menu item using "+" and "–".
u Press "OK".
ð The "Editable parameter" symbol appears.
u Change the menu item setting using "+" and "–".
u To save the setting, press "OK".
u To exit the standard menu, press "Menu".
ð The default display appears.
8.3
Configuration menu
Display
I1-I2
Pro1-Pro3
P1-P5
Calling up actual values, programming time programs and
setting parameters
u To call up the configuration menu, press and hold the but-
ton.
ð After approx. 3 seconds, actual value I1 is displayed.
u Use "+" and "–" to switch between the individual actual val-
ues, time programs and parameters.
u To exit the configuration menu, press "Menu".
ð The default display appears.
8.3.1 Actual values
Display Description
I1
Actual room temperature
Settings
Description
Actual values
Time programs
Parameter
Unit
[°C] | [°F]
|
21