Original operating manual
pilot-operated pressure regulators RP 824
NOTICE
Malfunction due to closure of the breather hole
External influences, e.g. covering, clogging or sticking of the breather hole, may cause a
malfunction. The valve no longer regulates reliably.
» The breather hole must be kept open!
NOTICE
Malfunction possible due to external influences
External influences, e.g. pressure on the breather hole, can cause control deviations or
damage internal parts.
» When cleaning the external surface, do not hold the high-pressure steam cleaner or the
compressed air gun near the breather hole!