Cable specifications
The sensor cable connection between sensor and transmitter has an EEx i type of
protection rating.
• The cables are available in lengths of 5 m, 10 m, 15 m and 30 m.
• You can choose between PTFE and PVC cable materials.
Caution:
Use the ready-to-use cables supplied by E+H with each sensor pair.
Connecting the sensor connecting cable
Warning:
Switch off the power supply before opening the connection compartment. Do not install
or wire the device while it is connected to the power supply. Failure to comply with this
precaution can result in irreparable damage to the electronics.
B
a
Fig. 4:
Connecting the two possible measuring systems (one or two-channel)
a = view B
1 = channel 1 upstream
2 = channel 1 downstream
3 = channel 2 upstream
4 = channel 2 downstream
4
3
2
1