Herunterladen Diese Seite drucken

Endress+Hauser PROline 93 II2G Serie Bedienungsanleitung Seite 41

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PROline Prosonic Flow 93 FOUNDATION Fieldbus

Endress+Hauser
Temperature tables
Prosonic Flow**PA*-A/B*****B/D***** and
Sound velocity measuring sensors DDU 18-A***
at T
= 60 °C
a
Sensors**PA*-A/B*****B/D*****
Sensors DDU 18-A***
The minimum medium temperature is –40 °C
Prosonic Flow**PA*-E/F*****B/D***** and
Sound velocity measuring sensors DDU 18-B***
at T
= 60 °C
a
Sensors**PA*-E/F*****B/D*****
Sensors DDU 18-B***
The minimum medium temperature is 0 °C
Wall thickness measuring sensor DDU 19-A***
at T
= 60 °C
a
Sensor DDU 19-A***
The minimum medium temperature is –40 °C
Transmitter Prosonic Flow 93 P**-************
The Prosonic Flow 93 transmitter has a T6 temperature class rating when installed in the
EEx d housing for operation at ambient temperatures up to T
The maximum ambient temperature range is –20...+60 °C.
Note:
At the specified medium temperatures, the equipment is not subjected to temperatures
impermissible for the temperature class in question.
T6
PVC cables
80
PVC cables
80
T6
PTFE cables
80
PTFE cables
80
T6
PVC or PTFE cables
80

Max. medium temperature [°C] in
T5
T4
T3
T2
80
80
80
80
80
80
80
80
Max. medium temperature [°C] in
T5
T4
T3
T2
95
130
170
170
95
130
170
170
Max. medium temperature [°C] in
T5
T4
T3
T2
80
80
80
80
= 60 °C.
a
T1
80
80
T1
170
170
T1
80
3

Werbung

loading

Diese Anleitung auch für:

Proline 93 ii21g serie