Herunterladen Diese Seite drucken

ROBBE Power Peak Quad EQ-BID 230 V Bedienungsanleitung Seite 36

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Power Peak® Quad EQ-BID 230 V
+/-
Button
+/-
Button
+/-
Button
7.2 SET-UP DISPLay
There is a separate Set-up menu with a corresponding screen display for each charge or
7.3
SETTINGS IN MaNUaL MODE
The following settings have to be entered manually before a charge or discharge pro-
cess can be started in manual mode; this ensures that the charger is able to work
through the process efficiently when in this mode:
Battery memory
Battery type
Cell count
Battery capacity (or battery voltage for LiPo, LiIo, LiFe and Pb)
Charge current
Discharge current
Buzzer (OFF, 1-5)
Note: Only values in the first line can be changed when the arrow symbol is flashing.
Operating Instructions
'ENTER'-
Button
'ENTER'-
Button
discharge parameter. The parameter to be chan-
ged is selected with the 'INC' or the 'DEC' button.
The corresponding line is indicated by an arrow
on the right-hand display margin. The set-up pro-
cedure is initiated by pressing ENTER. A '+' and
a '-' sign flash alternately on the right-hand screen
margin. A new value can be entered with the 'INC'
or the 'DEC' button. Press ENTER to confirm the
new setting. The illustrated display sequence
shows a typical example of how the charging cur-
rent is changed.
+/-