Laibungskanal
All manuals and user guides at all-guides.com
Soffit Element Installation Kit KWL 45 LE-RS/RSB / KWL 45 LE-RP
4 .0
Installation overview soffit element
Installation requirements soffit element:
1. Wall thickness of uncovered wall: min. 280 mm to max. 480 mm
2. The soffit element must always be overinsulated. It is not suitable for insulation thicknesses ≤ 100 mm and must not be
installed there.
3. Horizontal distance from core drilling hole to soffit (ready-mix plaster): min. 220 mm to max. 500 mm (see Fig. 6)
4. Vertical distance from core drilling hole to window lintel: min. 300 mm
5. Note the installation requirements for shutters and blinds!
6. Can be used for fire protection class B1 (flame resistant)
Rohbauwand + Fertigputz
Dämmstärke
Insulation thickness
Uncovered wall + ready-mix plaster
Soffit channel
100
ò
Wandeinbauhülse
Wall installation sleeve
( min. 300 )
ù
20 ± 3
74
Fig .4
min. 280
6
ò
Length of wall installation sleeve
Max.: 500 mm
Min.: 300 mm
The length of the wall installation sleeve com-
prises the thickness of the uncovered wall with
internal ready-mix plaster and the immersion
depth (
) in the soffit channel (see Fig. 4 & 5).
ù
m NOTE: The length of the wall installation
sleeve should be adjusted so that there are no
collisions in the area of the shutter rail.
If necessary, relining of the soffit channel on
site.
ù
Immersion depth of the wall installation
sleeve in the soffit element
Length: 20 mm
m NOTE: The wall installation sleeve must not
be cut off flush with the wall on the outside!
Distance from core drilling hole (centre)
ä
to the end of the soffit channel
Max.: 480 mm
Min.: 200 mm
The shortenable length of the channel must be
selected depending on the distance between
the core drilling hole (centre) to the ready-mix
plaster in the window soffit. This distance
minus the height of the shortened plaster fra-
me (
ë
) provides the length of the shortenable
area
ä
.
ë
Height of the plaster frame
Max.: 35 mm
Min.: 15 mm
The height of the plaster frame bridges the dis-
tance between the soffit channel and the wall
grille. The height must be selected depending
on the thickness of the window soffit insulation
and the ready-mix plaster. The plaster frame
allows for tolerance compensation.
A minimum height of 20 mm is recommended
for the plaster frame.