INSTALL THE OUTDOOR UNIT
3
DIMENSION DIAGRAM
Top view
980
Front view
(160)
660
Drain hole
Bottom view
Size
Water inlet port
Rc 1"
Water outlet port
• After selecting the best location, start installation according to Installation Diagram.
1. When installing at roof, please consider strong wind and earthquake. Please fasten the installation stand fi rmly
with bolt or nails.
2. When installing to a concrete or solid surface, use M10 or a W 3/8 bolts and nuts to secure the unit. Ensure that
it installed upright on a horizontal plane. (Use an anchor bolt for the installation as shown in the diagram below.)
DISPOSAL OF OUTDOOR UNIT DRAIN WATER
• When a Drain elbow 1 is used, please ensure to follow below:
- the unit should be placed on a stand which is taller than 50 mm.
- cover the ø32mm holes with Rubber cap 2 (refer to illustration below).
- use a tray (fi eld supply) when necessary to dispose the outdoor unit drain water.
• If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive
days, it is recommended not to use the Drain elbow 1 and Rubber cap 2 , for the drain
water freezes and the fan will not rotate.
Pressure relief valve drainage pipe-work
• Use a drain hose with inner diameter of 15mm.
• The hose must be installed in a continuously downward direction and left open to the frost-free
atmosphere.
• If drain hose is long, use a metal support fi xture along the way to eliminate the wavy pattern of drain hose.
• Water will drip from this hose, therefore the outlet of this hose must be installed in an area where the
outlet cannot become blocked.
• Do not insert this hose into sewage or drain pipe that may generate ammonia gas, sulfuric gas, etc.
• If necessary, use a hose clamp to tighten the hose at drain hose connector to prevent it from leaking.
8
430
Side view
160
511
Torque
88.2 N•m
It is advisable to avoid more than 2 blockage directions.
For better ventilation & multiple-outdoor installation,
please consult authorized dealer/specialist.
126
95
50
144
Rear view
Water outlet port
Pressure relief valve
connecting port
Connecting cable
Water inlet port
Rubber
cap 2
Illustration of how to fi x
drain hose to unit
More than
40mm
Base
Anchor bolt length
Drain
elbow 1
Pressure relief
valve connecting
port
Drain hose