6.2.1 Defining your own configuration combinations
Only one configuration entry is available. The special identification format
(special format) must be used for this. The manufacturer−specific data
specifies the contents and thus also the length of the input data and is 2 bytes
in length.
CFG entry no.
Meaning
0
channel 1
The following input and output data can be configured for the cyclical data
communication. The choice of which data is actually transferred is
communicated via the manufacturer−specific data of the special identification
format.
Configuration
Length of cyclical data
manufacturer−
specific data
Byte no.
Bit no.
0
0
0
1
0
2
0
3
0
4
0
5
0
6
1
0
1
1
1
2
1
3
1
4
Tab 6.3:
Selecting the data content via the manufacturer−specific data
The length of the input data is the sum of all the data lengths selected for the
communication in words. When selecting the 32 bit format and the float format
for measured values, the length values in brackets must be used.
A0623-6.1 en/de/fr
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
special format with inputs and outputs, maximum 9 words
output, maximum 13 words input, 2 bytes comment length
Length of cyclical data
inputs
(words)
1(2)
1(2)
1(2)
1(2)
1(2)
1
2
Contents
(data)
Contents of cyclical
outputs
(words)
Peak−to−peak
Output values:
1
1(2)
Limit value level 1
1(2)
Limit value level 2
1(2)
Limit value level 3
1(2)
Limit value level 4
15
data
Input values:
Gross
Net
Max
Min
Status1
Status2
Control word