6.2 Configuration
The configuration defines which data content is exchanged in the cyclical data
communication. The following data is available for selection:
Input values:
Name
Gross
Net
Max
Min
Pk−Pk
Status1
status word with status of the limit switches and gen. error
Status2
Output values:
Name
Control word
control word for triggering taring, zeroing, clearing the peak
Limit1
Limit2
Limit3
Limit4
The formats of the cyclically communicated data content are specified in detail
in chapter 6.3. The measured values are offered optionally as a 16-bit integer,
32-bit integer or 32 bit float. The values are always scaled to physical size
with the number of decimal places of your choice. Information on whether the
16 bit format or a 32 bit format is used and on the number of decimal places is
defined in the parameter assignment message.
Typical combinations are predefined in the GSD file. If you require other
combinations you can expand the GSD file accordingly using the following
specifications.
HBM
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
gross measured value
net measured value (gross minus tare value)
contents of the maximum store
contents of the minimum store
peak−to−peak, difference between max and min
double status word with differentiated error flagging
value store, parameter set selection, etc.
level at which limit switch 1 responds
level at which limit switch 2 responds
level at which limit switch 3 responds
level at which limit switch 4 responds
Meaning
bits
Meaning
PME−MP60DP
Length
1 or 2
words
1 or 2
words
1 or 2
words
1 or 2
words
1 or 2
words
1 word
2 words
Length
1 word
1 or 2
words
1 or 2
words
1 or 2
words
1 or 2
words
A0623-6.1 en/de/fr