Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time =100%)
Flow Rate
System Error
Communication Watchdog alarm
Calibration Function
Default parameters:
•
Language = UK
•
Set Point value= 7,4 pH; 750mV (Rx)
•
Dosing Method = Acid; Low (Rx)
•
Time OFA = OFF
•
Calibration = 7/4 (2 point); 465mV (Rx)
•
Flow Input = OFF
Code 0000138008
Display
Level____7,2_ph
OFA_Alarm__7,2_ph
OFA_STOP___7,2_ph
Error_465_mV
To restore Default parameters run Following steps:
rev. 1.0
Relay
Alarm Relay
Close
Alarm Relay
open
Alarm Relay
Close
Alarm Relay
open
Alarm Relay
Open
Alarm Relay
Close
Alarm Relay
open
•
Power off Pool Basic unit
•
Keeping Press UP and DOWN Key switch on the
Power.
Init.default__no
•
The unit will flash
•
Press up
•
Enter Key to restore Default parameters.
Actions to do
- Push Enter Key to open
Alarm Relay
- Restore Product tank
- Push Enter Key to reset
- Push Enter Key to reset
- Restore Flow Rate
- Press Enter Key to replace
Default parameter
- Check the communication
network
- Restore Probe or Buffer
solution and repeat calibration
function
7